SORIN GROUP is a global medical device company and a leader in the treatment of cardiovascular diseases.
The Company develops, manufactures and markets medical technologies for cardiac surgery and for the treatment of cardiac rhythm disorders.

Over 40 years of excellence in Research and Development.

We devote $70.1 million to R&D, accounting for over 9,4% of sales.

15% of our employees (over 500 people) work in R&D in centers in North America, France, Italy and Germany.

Our multidisciplinary teams bring together researchers from different backgrounds to offer a broad range of technical and scientific expertise.Our “Engineer-Physician intelligence Networks” provide a continuous source of knowledge and ideas in order to develop innovative therapeutic solutions for patients and healthcare professionals.

We have forged partnerships with cardiology specialists at world renowned universities and research centers across the globe.Our portfolio contains over 2,000 patents.

www.sorin.com

sorin logo

Sorin Leads

Bradycardia Leads
Defibrillation Leads
Heart Failure Management Leads

 

BRADYCARDIA LEADS

BEFLEX

EASY1, FAST2 and SAFE3

beflex bradycardia lead

  • Pin driven extendable/retractable helix
  • 6F lead body, 7F introducer
  • High flexibility thanks to silicone insulation

beflex bradycardia lead

 

XFine
Responsive Technology in your Hands

xfine bradycardia lead

  • 4.8F lead body
  • Optimal lead handling characteristics4
    Polyurethane overlay: Slippery
  • Redundant insulation: Teflon5 Polyurethane overlay5,6

xfine bradycardia lead

top

DEFIBRILLATION LEADS

ISOLINE
The First in a Long Line of Leaders

isoline defibrillator lead isoline defibrillator lead


  • Steroid Eluting
  • Polyurethane overlay:n Abrasion resistance7
  • Multi-lumen Technology
    Multi-lumen silicone construction Redundant insulation8
  • 7.8 F body lead diameter
    Very good lead handling characteristics9
    Fast lead placement time10

isoline defibrillator lead

top

HEART FAILURE MANAGEMENT LEADS

SonRtip
The technology is in the tip

sonr tip lead
SonRtip is the only atrial pacing lead featuring an embedded hermetically-sealed micro-accelerometer11
The micro-accelerometer functions as a sensor providing access to exciting new technologies in the treatment of heart failure:

  • Measures the vibrations that correlate to S1 heart sounds
  • Connects to the only CRT-D system able to measure real-time contractility and automatically optimizes timing cycles at rest and exercise

 

More than an atrial lead

While the SonRtip lead functions as a standard atrial lead, it also functions as a sensor to measure vibrations that correlate to heart sounds12
The SonRtip lead:

  • Can be easily implanted anywhere in the atrial wall12
  • Accurately measures cardiac muscle vibrations that reflect the first heart sound from any position in the atrium

SonRtip SENSOR – KEY FEATURES

sonr tip lead

  • The SonRtip sensor is a piezoceramic transducer loaded by a platinum/iridium seismic mass, converting flexural stresses to electricity
  • A micro spring integrated into the sensor increases sensitivity while providing additional protection and shock resistance
  • The sensor signal is amplified and transmitted to the PARADYM™RFSonR CRT-D device through a micro electronic circuit to ensure long-term signal integrity

sonr tip lead

top

Situs OTW

situs otw lead

Left ventricular Over The Wire lead
Unique tip design for truly stable positioning
The silicone screw design at the tip of the lead body makes the lead "actively fixated" in the lumen of the vein

situs otw lead

  • Significantly lower risk of dislodgement
  • Safe extraction of the guiding catheter due to efficient fixation

situs otw lead

top

___________________________________________________________________________

Beflex
1. 99% of clinical evaluation investigators concluded that BeFlex leads had either "equal", "better" or "the best" X-ray visibility of the lead body in the atrium when compared to other similar models typically used by investigators; 97% of investigators concluded that BeFlex leads had either "equal", "better" or "the best" maneuverability in the ventricle; 95% of investigators concluded that BeFlex leads had either "equal", "better" or "the best" overall ease of lead placement in the ventricle; 94% of investigators concluded that BeFlex leads had either "equal", "better" or "the best" Ease of extension/retraction of helix in the ventricle.
2. 97% of clinical evaluation investigators concluded that BeFlex leads had either "equal", "better" or "the best" Lead advancement through the vein in the atrium when compared to other similar models typically used by investigators; 96% of investigators concluded that BeFlex leads had either "equal", "better" or "the best" Lead tip positioning in the ventricle; 94% of investigators concluded that BeFlex leads had either "equal", "better" or "the best" Lead placement time in both the atrium and the ventricle.
3. During clinical evaluation, it has been demonstrated that the BeFlex leads provided low acute pacing thresholds and satisfying impedance values in both cavities. The amplitudes, impedance values and thresholds were stable during the one month follow up; In the clinical evaluation, the sponsor noted that the preliminary clinical data has provided sufficient proof that the Beflex lead is safe and effective for its intended use.

___________________________________________________________________________

XFine
4. In clinical evaluations, 100% of investigators concluded that the X FINE TX26D lead had equal or better vein advancement characteristics than other models. 88.7% and 90.1% of investigators concluded that the X FINE TX26D had equal or better maneuverability characteristics through the tricuspid valve and in the chamber respectively, than other models.

5. Polyurethane, ETFE coating, Silicone.
6. In clinical evaluations, 98.6% of investigators concluded that the X FINE TX26D was equal or more slippery than other models used for implant.

___________________________________________________________________________

Isoline

7.Results in an internal study demonstrate that a similar lead with the same polyurethane overlay, UW28D is at least 201 times more resistant to abrasion in this model than the non-polyurethane coated+UC28D lead (465179 / 2312 = 201).
8.Redundant Insulation: ETFE coating, Silicone 3.In clinical evaluations, 100% of investigators had a good or very good overall impression of the Isoline 2CT lead handling characteristics.
9.In clinical evaluations, 83.3% of investigators had a good or very good overall impression of the Isoline 2CR lead handling characteristics.
10. In clinical evaluations, 70% of investigators characterized the lead placement time of Isoline 2CR as fast and 64% of investigators characterize the lead placement time of Isoline 2CT as fast.

___________________________________________________________________________

SonRtip

11. Sorin Group Data on file.
12. Sorin Group Data on file. Report REP 1676B.